Short answer. You can often add panels, but your inverter sets the limit. Where it is full or old, the answer is a second inverter or a replacement, and new panels normally need their own string. Extra panels can earn STCs as an extension system, and Essential Energy needs a new connection application.
★★★★★ Rated 5.0 from 66 Google reviews · read them on Google · read them on our reviews page
If your solar system has been working well and your needs have grown, you may be thinking about more panels. Sometimes that is a simple add-on, and sometimes the inverter is the real limit. Here is how we think it through.
How much would it cost for your home? See a typical price range in about a minute with our free solar and battery price calculator.

Your inverter is the main limit, and the first thing we check:
Panels in a string share the same current, so the weakest one sets the pace. New, higher-wattage panels on the same string as older, smaller ones will usually be held back to the older panels’ level. Panels facing different directions also need separate inputs. For that reason we normally keep new panels on their own input, string or inverter. If a roof face is shaded, we say so before we recommend panels.
We install AIKO and Jinko panels. Both are N-type panels and installers rate them highly. AIKO suits tight roofs and partial shade, and Jinko suits straightforward roofs with room. See AIKO vs Jinko. The new panels are chosen to suit what is already on the roof and what the inverter can take.
We are straight with you if an old system is not worth extending. We only service systems we can properly support.
Sometimes. It depends on your inverter’s capacity, its panel inputs, the roof space and your Essential Energy connection. Where the inverter is at its limit, the options are a second inverter or replacing the inverter. We check on the site visit.
Often yes, but not on the same string. Panels of different wattage, age or brand should not share a string, because the weakest panel drags the string down. We normally put new panels on their own input or their own inverter.
They can. The Clean Energy Regulator treats an addition as an extension system, the components must be approved, and the whole system after the upgrade cannot exceed 100 kW. Replacing panels that already received STCs does not earn more.
Yes. A change to a connected solar system usually needs a connection application, and your export limit may apply to the new total. We prepare and submit it for you.
It depends on when you use power. If your problem is evening use, a battery usually does more than extra panels. If you are importing power during the day, more panels can help. We look at your bills and tell you.